Mercury F515 Fluorescence Endotoxin Detector
Mercury F515 Fluorescence Endotoxin Detector
The Mercury F515 Fluorescence Endotoxin Detection System is a high-sensitivity microplate fluorometer designed by integrating innovative linear PMT detection technology with dual-excitation light source compensation technology, offering a wide dynamic range and excellent linearity. Its temperature control system can reach up to 45°C, ensuring reaction uniformity and well-to-well detection repeatability. Compact and lightweight, the system comes with proprietary software developed in-house, which supports preset experimental protocols and templates, one-click report generation, and clear, at-a-glance results to meet user needs.
Mercury F515
Fluorescence Endotoxin Detector
Specialized for recombinant Factor C detection. High sensitivity, high dynamic range and high linearity. Independently developed software and equipment.
FEATURE
DESCRIPTION
Specialized Design
Specialized for recombinant Factor C detection, providing professional reports. New methodology support for rFC detection.
High Performance
Innovative linear PMT detection technology and dual excitation light source compensation. Dynamic range extended to 10⁷, 100× wider than conventional.
Temperature Control
Built-in temperature control up to 45°C. High uniformity system ensures reaction consistency and inter-well repeatability.
Confocal Optical System
Confocal technology effectively suppresses environmental stray light and minimizes cross-interference from adjacent wells.
Software & Automation
Process-based user management. One-click experiment, calculation and report. Expandable with EndoMaster series for fully automated operation.
Target Users
Pharmaceutical manufacturers · Biopharma · Research institutes · QC laboratories
Catalog: Mercury F515 · Compatible with EndoMaster Series
Mercury F515
Technical Specifications
Instrument parameters and performance indicators for the Mercury F515 fluorescence endotoxin detector.
Category
Parameter
Specification
Optical
Excitation Channel
370nm (bandwidth 40nm)
Optical
Emission Channel
436nm (bandwidth 20nm)
Temperature
Control Range
Room temperature ~ 45°C
Temperature
Accuracy
±0.5°C
Temperature
Uniformity
< 1%
Detection
Dynamic Range
0 ~ 650,000
Detection
Standard Curve Linear
R ≥ 0.980
Detection
Repeatability
< 3%
General
Dimensions / Weight
345×248×210mm · 9kg
Microplate
Endotoxin-free 96-well plate · Detachable black 8-well strip
Power Supply
AC220V, 50/60Hz
Catalog: Mercury F515 · Matching Kit: Bioendo™ rFC Endotoxin Test Kit