Xiamen Bioendo Technology Co., Ltd Official Website
  • Home
  • Products
  • End-Point Chromogenic Endotoxin Test TAL Kit Without Diazo Reagent
Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay)
Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay)试剂瓶
Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay)
Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay)试剂瓶
Bioendo EC Endotoxin Test Kits provide a kind of measurement for quantitative endotoxin testing solution. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored product with maximum absorbance at 405nm. For End-point Chromogenic Endotoxin Test Kit without Diazo Coupling, a regular spectrophotometer or microplate reader is required to read the absorbance at 405nm. The regular spectrophotometer with the function of kinetic experiment, the accuracy of temperature control and 405nm filter, then use that spectrophotometer can read the quantitative endotoxin result of EC kit.
Catalog No.Description & Kit ContentsSensitivity Range
EC6440564 Tests/Kit
               2 Lyophilized Amebocyte Lysate, 1.7ml/vial;
               2 Water for BET, 50ml/vial;
               2 CSE;
               4 Chromogenic Substrate, 1.7ml/vial
0.1-1 EU/mL
EC64405S0.1-1 EU/mL;0.01-0.1 EU/mL
The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis, MSDS.
Note:  For other sizes/specifications not listed above, please contact our customer service team.
Email:  Eve@bioendo.com
Tel:  +86 18065928551

PHARMACOPOEIA COMPLIANCE
CHP · USP · EP · JP Compliant
Compliant with major pharmacopoeial requirements including CHP, USP, EP and JP for bacterial endotoxin testing.
QUANTITATIVE DETECTION
Chromophore Release Quantification
Determines endotoxin concentration based on chromophore release, providing accurate quantitative results.
       
HIGH SENSITIVITY
0.01–0.1 or 0.1–1 EU/mL
Available sensitivity range: 0.01–0.1 EU/mL or 0.1–1 EU/mL.
MICRO-VOLUME TESTING
Small-Volume Sample Efficiency
Designed for quantitative testing of small-volume samples with reduced reagent consumption.
ANTI-INTERFERENCE
Optimized Chromogenic Detection
Provides reliable results for complex samples through optimized chromogenic detection technology.
HIGH-THROUGHPUT
96-Well Microplate Compatible
Compatible with pyrogen-free 96-well microplates, reagent reservoirs and multichannel pipettes for improved efficiency.
EQUIPMENT COMPATIBILITY
Flexible Detection Platforms
Can be performed using temperature-controlled microplate readers or constant-temperature heating devices.
RELATED EQUIPMENT
Compatible Endotoxin Detection Systems
Compatible instruments support different endotoxin detection workflows, from routine laboratory testing to fully automated analysis.
PRODUCT
DESCRIPTION
Full Wavelength Absorption Light Bacterial Endotoxin Detector
Fluorescent Endotoxin Detection Instrument
Multifunctional Endotoxin Detector
Bacterial Endotoxin Detector
Intelligent Fully-Automatic Endotoxin Detection System
Phoenix Q9
Intelligent Fully-Automatic Endotoxin Detection System
Modular Intelligent Fully-Automatic Endotoxin Detection System
Click the product name to view product details.